StruxureWare Data Center Expert Integration

StruxureWare Data Center Expert is easy to use and deploy with a user-friendly interface to monitor, manage and control the hundreds or thousands of devices a company might have from a wide range of manufacturers. These devices include equipment that provides power, cooling, security and environmental monitoring.

288

What does Opsgenie offer StruxureWare Data Center Expert users?

Use Opsgenie’s StruxureWare Data Center Expert Integration you can forward StruxureWare Data Center Expert alerts to Opsgenie. Opsgenie determines the right people to notify based on on-call schedules– notifies via email, text messages (SMS), phone calls and iPhone & Android push notifications, and escalates alerts until the alert is acknowledged or closed.

Functionality of the integration

  • When an alert is created in StruxureWare Data Center Expert, it creates an alert in Opsgenie.

Add StruxureWare Data Center Expert Integration in Opsgenie

  1. Please create an Opsgenie account if you haven't done so already.
  2. Go to Opsgenie's StruxureWare Data Center Expert Integration page.

🚧

For Free and Essentials plans, you can only add the integrations from the Team Dashboards, please use the alternative instructions given below to add this integration.

  1. Specify who is notified of StruxureWare Data Center Expert alerts using the Teams field. Autocomplete suggestions are provided as you type.

📘

An alternative for Step 2) and Step 3) is to add the integration from the Team Dashboard of the team which will own the integration. To add an integration directly to a team, navigate to the Team Dashboard and open Integrations tab. Click Add Integration and select the integration that you would like to add.

  1. Copy the Webhook URL.
  2. Click Save Integration.
2500

Configuration in StruxureWare Data Center Expert

  1. Create an Alert Action to use "Send HTTP Post" alert notifications in StruxureWare Data Center Expert.
  2. Double-click the Alert Actions icon.
  3. Click Add... to open the "Add Alert Action" window.
  4. Select "Send HTTP Post" and click OK.
  5. Enter a name for this alert action in the "Alert action name" field.
  6. Select the language and territory using the "Locales" drop-down list.
  7. Enter the maximum number of available images included with the generated data in "Maximum Camera Pictures".
  8. Check "Include a graph with the alert" to include a graph of the sensor values associated with the alert in the data.
  9. Check "Include a sound clip with the alert" to include audio captured by the camera pod in the data.
  10. Check "Include Related Maps with the Alert" to include maps showing the sensor that generated the alert action.
  11. Specify "Advanced Scheduling" (optional). By default, all Alert Actions are active 24 hours a day, 7 days a week. Specify an Alert Action to be activated only when alert conditions occur during specific time ranges. To configure Advanced Scheduling:
    • Click Advanced Scheduling.
    • By default, all time periods are "Enabled". Click-and-drag to highlight the time range, and click Disable to disable the alert action. Click-and-drag to highlight the time range, and click Enable to enable a disabled time range.
  • Click OK to save the schedule and return to the "Add Alert Action" window.
  1. Check the alert Severities that apply to buttons to be activated.
  2. Paste the Webhook URL copied previously from Opsgenie's integration page into Target URL in the Basic tab.
  3. Type Opsgenie to the "Target User ID" field and 123 to the "Target Password" field under the "Basic" tab. The values in the Target User ID and Target Password fields have no effect on the integration.
  4. In the "Advanced" tab, enter the backup information for the "Target URL", and enter any "SSL verification options" in SSL Verify Options.
  5. Click OK to save this Alert Action.